{"product_id":"medtronic-guardian-4-sensor-for-minimed-780g-5-pack","title":"Medtronic Guardian 4 Sensor for MiniMed 780G (5 Pack)","description":"\u003ch1\u003eMedtronic Guardian 4 Sensor\u003c\/h1\u003e\n\u003cp\u003eThe Guardian 4 sensor is a device that helps people with diabetes manage their glucose levels. It's part of the Continuous Glucose Monitoring (CGM) system and works by converting tiny amounts of glucose from under the skin into an electronic signal. This signal then provides information about glucose levels, helping people make informed decisions about their treatment.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Guardian 4 sensor is designed to complement, not replace, the information obtained from standard blood glucose monitoring devices. It's a single-use device that can be used for up to seven days and doesn't require a prescription. Users can refer to the system user guide to make treatment decisions based on the sensor's readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor use with the MiniMed™ 780G system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eMiniMed Guardian Sensor 4 Features: \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMedtronic's most accurate sensor with a MARD* rating of 8.7%\u003cspan\u003e \u003c\/span\u003eusing the CONTOUR\u003csup\u003e®\u003c\/sup\u003eNEXT LINK 2.4 Meter\u003c\/li\u003e\n\u003cli\u003eEasy to insert\u003c\/li\u003e\n\u003cli\u003eFlexible design moves with your body for ultimate comfort\u003c\/li\u003e\n\u003cli\u003eKnow at all times where your glucose levels are trending\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContains 5 MiniMed Guardian 4 Sensors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMedtronic Guardian 4 User guides\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Guardian™ 4 Sensor user guide (pdf)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1702\/1747\/files\/Guardian_4_sensor_user_guide.pdf?v=1702486943\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eGuardian™ 4 Sensor user guide (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Guardian™ 4 Transmitter user guide (pdf)\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1702\/1747\/files\/Guardian_4_transmitter_user_guide.pdf?v=1702487424\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eGuardian™ 4 Transmitter user guide (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eHow to Remove the Guardian 4 Sensor\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect the transmitter from the sensor as described in the Guardian 4 transmitter user guide.\u003c\/li\u003e\n\u003cli\u003eGently pull the sensor from the body to remove it.\u003c\/li\u003e\n\u003cli\u003eDiscard the sensor in a sharps container.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRead this entire user guide before attempting to insert the Guardian 4 sensor. The one-press serter (MMT-7512) is the only serter approved for use with the sensor. Failure to follow directions or using a different insertion device, may result in improper insertion, pain, or injury.\u003c\/p\u003e\n\u003cp\u003eDo not attempt to connect a transmitter or recorder that is not compatible with the sensor. The sensor is designed to work with approved transmitters only. Connecting the sensor to a transmitter or recorder not approved for use with the sensor may damage the components. Refer to the system user guide for a list of compatible products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrecautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eBefore inserting the sensor, wash your hands with soap and water to prevent any site infection.\u003c\/li\u003e\n\u003cli\u003eDo not insert the sensor through tape, which may cause improper insertion and function.\u003c\/li\u003e\n\u003cli\u003eUse only alcohol to prepare the insertion site and ensure that no residue is left on the skin.\u003c\/li\u003e\n\u003cli\u003eRotate the sensor insertion site to ensure the sites are used effectively.\u003c\/li\u003e\n\u003cli\u003eDo not attempt to clean, resterilize or extract the needle from the needle housing, as this may cause accidental needlestick or puncture.\u003c\/li\u003e\n\u003cli\u003ePlease do not reuse the sensor; it may damage the sensor surface and lead to inaccurate glucose values, site irritation, or infection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Medtronic","offers":[{"title":"Default Title","offer_id":48530268750053,"sku":"MMT7040A","price":249.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9921\/1493\/files\/1000_DW_P__guardian2.jpg?v=1773101759","url":"https:\/\/discountdiabeticstore.com\/products\/medtronic-guardian-4-sensor-for-minimed-780g-5-pack","provider":"Discount Diabetic Store","version":"1.0","type":"link"}